Part 1 – Commands for All Universal IP Devices
&W – Store Factory Defaults to NVM
Chapter 1 – General AT Commands
Description:
Syntax:
Values:
For MT100SEM: Stores factory defaults to the NVM.
For NON-MT100SEM: Stores the current settings of &D, &S, &C, E, and V only.
AT&W
None
+ICF – DTE-DCE Character Framing
Description:
Syntax:
Values:
This command determines the local serial port start-stop (asynchronous) character framing that
the DCE uses.
AT+ICF= <format value>[, <parity value>]
<format>
0
1
2
3
4
5
6
Autodetect (not supported)
8 Data 2 Stop (supported)
<parity> parameter is ignored
8 Data 1 Parity 1 Stop (supported)
If no <parity> provided, 3 is used by default as <parity> value
8 Data 1 Stop (supported)
<parity> parameter is ignored
7 Data 2 Stop (supported)
<parity> parameter is ignored
7 Data 1 Parity 1 Stop (supported)
If no <parity> provided, 3 is used by default as <parity> value
7 Data 1 Stop (supported)
<parity> parameter is ignored
<parity>
0
1
2
3
4
Odd (supported)
Even (supported)
Mark (supported)
Space (supported)
None (supported)
Default:
Format: 2
Parity: 4
Default Example: AT+ICF= 2,4
+IFC – Set Flow Control
Description:
Syntax:
Values:
Turns flow control on and off.
AT+IFC=<flow control value>
0,0 Flow Control Off
2,2 Flow Control On
Default:
Examples:
2,2
Flow Control On
+ICF input values
Resulting affect
Format Parity
1 0-4, blank (ignored)
2 0-4, blank
3 0-4, blank (ignored)
4 0-4, blank (ignored)
5 0-4, blank
6 0-4, blank (ignored)
Data bits
8
8
8
7
7
7
Stop bits
2
1
1
2
1
1
Parity
None
0-4; 3 if the input is left blank
None
None
0-4; 3 if the input is left blank
None
Universal IP AT Commands Reference Guide (Document S000457G)
12
相关PDF资料
MT5692SMI-X-L-92 V.92 SERIAL DATA
MT9234MU MODEM V.92 DATA/FAX USB WORLD
MT9234ZBA-NAM MODEM V.92 WORLD DATA/FAX
MT9234ZBA-USB-CP MODEM V.92 DATA/FAX USB WORLD
MT9234ZBA-USB MODEM V.92 DATA/FAX WORLD USB
MT9234ZPX-PCIE-CP MODEM V.92 DATA/FAX/VOICE WORLD
MT9M032I12STCH ES KIT HEAD BOARD FOR MT9M032
MT9T031P12STCH ES KIT HEAD BOARD FOR MT9T031
相关代理商/技术参数
MT5692SMI-V-34.R1 功能描述:拨号模块 V.34 Serial Data/Fax Speakerphone 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-34.R1-SP 功能描述:拨号模块 V.34 Serial Data/Fax Speakerphone 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-34-SP 功能描述:拨号模块 V.34 Serial Data/Fax 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-92 功能描述:拨号模块 V.92 Serial Data/ V.17 Fax/Voice-5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-92.R1 功能描述:拨号模块 V.92 Serial Data/Fax Speakerphone 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-92.R1-SP 功能描述:拨号模块 V.92 Serial Data/Fax Speakerphone 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-V-92-SP 功能描述:拨号模块 V.92 Serial Data/Fax 5V RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm
MT5692SMI-X-L-92 功能描述:拨号模块 V.92 Serial Data/Fax 3.3V No LED Pins RoHS:否 制造商:Multi-Tech Systems 产品:Data / Fax Modems 最大数据速率:56 kbps 存储类型:Flash 接口类型:Serial 工作电源电压:3.3 V 工作电源电流:95 mA 功耗:310 mW 最大工作温度:+ 70 C 尺寸:64.5 mm x 26.5 mm x 17 mm